Showing results: 316 - 330 of 374 items found.
-
VFL135106-020 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 200 pin Male LFH to TriPaddle Leads, 28AWG Twisted Pairs - MULTI LEG 100 T/P's (1:2) 200 connection points, 4-40 fastener, VPC: 441655000-1, for 40-148-101, 40-148-201, 40-148-001, 40-140A-221, 40-140A-121, 40-140A-021, 40-670C-022 families, VPC contact 610110167 - TRI RCV (26-28AWG) (7 AMP/4 mΩ MAX), 20" length.
-
VFL159124-036 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 36" length.
-
VFL159124-072 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 72" length.
-
VFL159124-060 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 60" length.
-
VFL159124-048 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 48" length.
-
VFL103124-072 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female DIN to QuadraPaddle Leads, 24AWG Twisted Pair, 80 T/P's(1:2) 160 connection points, M2.5 x .45 fastener, CONN: 024070 WIRE: VPC, for PXI-2737, PXIe-2738 families, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 20" length.
-
156166-01 -
NI
SHC68-C68-RDIO2 Shielded R Series High Speed Digital Male VHDCI Cable, 1m
-
156166-02 -
NI
SHC68-C68-RDIO2 Shielded R Series High Speed Digital Male VHDCI Cable, 2m
-
191667-01 -
NI
68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable 1m
-
40-201-004 -
Pickering Interfaces Ltd.
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-201-008 -
Pickering Interfaces Ltd.
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-190B-402 -
Pickering Interfaces Ltd.
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
40-190B-302 -
Pickering Interfaces Ltd.
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-502 -
Pickering Interfaces Ltd.
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
50-190-201 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.